Installation

1. Position the A/C condenser core assembly to the radiator supports . Install the retaining screws and tighten to 2.7-3.7 N.m (24-32 lb-in).
2. Connect the refrigerant lines to the A/C condenser core assembly using procedures for connecting spring lock couplings.
3. Install the radiator.
4. Connect the battery ground cable.
5. Leak test, evacuate and charge the refrigerant system following the recommended procedures and safety precautions.