mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Hose/Line HVAC > < A/C High Pressure Safety Valve|Page 9228
Page 1
background image

High Pressure Safety Valve HVAC: Service and Repair

Removal

1. Discharge refrigerant from system. Observe all safety precautions.
2. Raise vehicle.
3. Remove A/C pressure relief valve deflector from A/C compressor pressure relief valve.
4. Remove A/C compressor pressure relief valve from A/C manifold and tube.

Installation

1. Follow removal procedure in reverse order.
2. Use new O-ring seal lubricated with clean Motorcraft YN-12b refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B.

Hose/Line HVAC > < A/C High Pressure Safety Valve|Page 9228