Cougar/XR7 V8-4.6L VIN W (1997)
Power Steering Pump: Pressure, Vacuum and Temperature Specifications
Flow Rate [1]
Minimum Flow [2] ................................................................................................................................................................. 5.3 L/min (1.4 gallons/min)
Maximum Flow [3] ................................................................................................................................................................ 10.2 L/min (2.7 gallons/min)
Relief Pressure [1]
Minimum ............................................................................................................................................................................................ 8275 kPa (1200 psi)
Maximum ........................................................................................................................................................................................... 9520 kPa (1380 psi)
[1]
Fluid should be at 78°C (172°F) and 5100 kPa (740 psi) at 675 rpm. Vehicle at Zero speed (not moving).
[2]
Flow depends on pump model, engine rpm and pulley drive ratio. Engine idle rpm must be set to specification when checking pump minimum flow
capacity.
[3]
Maximum Free Flow @ 1500 rpm.