7. Disconnect motor drive assembly.

 

8. Remove motor drive assembly.

 

9. Remove regulator.

 

Installation

1. Install regulator.

 

2. Install motor drive assembly through access hole.

 

3. Assemble motor drive assembly to drum housing and cover. Align mounting holes in motor with holes in drum housing and cover.

 

4. Align motor drive assembly to mounting bracket.

 

5. Install three retaining screws to mounting bracket. Tighten to 5.5-7.0 N-m (49-61 lb-in).

 

6. Connect motor wire to harness.

 

7. Remove clamp and check window operation.

 

8. Install watershield and door trim panel. See: 

CAUTION:

When servicing regulator assembly, regulator cable tension must not be altered. Cable tension is preset at production. Improper adjustment may result in
premature regulator failure or erratic operation.