mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Master Power Window Switch|Page 9843 > < Master Power Window Switch
Page 2
background image

5. Remove the test lead from terminal 3 and connect it to terminal 2 (hot feed pin). With all switches in the NEUTRAL position, only terminal 1

should have continuity to terminal 2. 

  

6. Push all four switches forward and hold in that position. Terminals 5, 7, 9 and 11 should have continuity to terminal 2. 

  

7.    Pull all four switches rearward and hold in that position. Terminals 4, 6, 8 and 10 should have continuity to terminal 2. 

  

8. Push the lock out switch to its detent position. Terminal 2 should not have continuity with any other terminal. 

  

9. If any switch does not test as stated, replace the complete switch assembly. 

  

Master Power Window Switch|Page 9843 > < Master Power Window Switch