Heater System Electrical Wiring Diagram And Continuity Test

These images contain system vacuum schematics and vacuum motor charts which illustrate vacuum routings and air flow during the various system
conditions. Also the system electrical wiring diagram including test information.

OFF
In OFF position the outside air door is in the closed (full vacuum) position. The panel door is in the no vacuum position, and the floor-defrost door
is in the floor (full vacuum) position. The blower is off and the temperature blend door maintains a position depending on the temperature control
lever position.

VENT
When the function lever is in the VENT position, the outside air door is opened to admit outside air into the system (no vacuum). The panel door
is in the PANEL position (vacuum) and the air is distributed out of the instrument panel registers. The floor-defrost door is also applied with full
vacuum, directing a small amount of air to the floor area. The outside air can be heated to a higher desired temperature by moving the temperature
lever toward WARM.