mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Vacuum Reservoir HVAC > < A/C Cycling Switch|Page 4968
Page 1
background image

Service Port HVAC: Description and Operation

Air Conditioning

Service Gauge Port Valves

The high-pressure service gauge port valve is located on the compressor-to-condenser discharge line.

The low-pressure service gauge port valve is located on the suction accumulator.

The fitting is an integral part of the refrigeration line or component.

-

Special couplings are required for both the high-side and low-side service gauge ports.

-

A very small amount of leakage will always be detectable around the Schrader-type valve with the service gauge port valve cap removed, and is
considered normal. A new Schrader-type valve core can be installed if the seal leaks excessively.

-

The service gauge port valve caps are used as primary seals in the refrigerant system to prevent leakage through the Schrader-type valves from
reaching the atmosphere. Always install and tighten the A/C service gauge port valve caps to the correct torque after they are removed.

Vacuum Reservoir HVAC > < A/C Cycling Switch|Page 4968