Intake Air Duct: Service and Repair

Engine Air Cleaner

REMOVAL AND INSTALLATION

1. Loosen engine air cleaner intake collars and remove air cleaner outlet tube retaining bolt.
2. Disconnect crankcase ventilation tube and idle air control valve inlet tube from air cleaner outlet tube and remove air cleaner outlet tube.
3. To install, reverse removal procedure. Tighten air cleaner outlet tube retaining nut to 2.3-3.4 N,m (20-30 lb in). Tighten engine air cleaner tube

clamps to 3.4-4.6  Nm (30-41 lb in).