Page 1
background image

Brake Bleeding: Service and Repair
Component Bleeding

Component Bleeding 

Special Tool(s)

Material

Master Cylinder Priming - In-Vehicle or Bench 

WARNING:  Use of any brake fluid other than approved DOT 3 will cause permanent damage to brake components and will render the
brakes inoperative. Failure to follow these instructions may result in personal injury.
 

WARNING:  Brake fluid contains polyglycol ethers and polyglycols. Avoid contact with eyes. Wash hands thoroughly after handling. If
brake fluid contacts eyes, flush eyes with running water for 15 minutes. Get medical attention if irritation persists. If taken internally, drink
water and induce vomiting. Get medical attention immediately. Failure to follow these instructions may result in personal injury.
 

CAUTION:  Do not allow the brake master cylinder reservoir to run dry during the bleeding operation. Keep the brake master cylinder reservoir filled
with the specified brake fluid. Never reuse the brake fluid that has been drained from the hydraulic system.

CAUTION:  Brake fluid is harmful to painted and plastic surfaces. If spilled, wipe up immediately before damage to the painted or plastic surface
occurs.

NOTE:  When any part of the hydraulic system has been disconnected for repair or installation of new components, air can enter the system and cause
spongy brake pedal action. This requires bleeding of the hydraulic system after it has been correctly connected. The hydraulic system can be bled
manually or with pressure bleeding equipment.

NOTE:  When a new brake master cylinder has been installed or the system has been emptied, or partially emptied, it should be primed to prevent air
from entering the system.

1. For in-vehicle priming, disconnect the brake lines.

Component Bleeding|Page 5939 > < Wheel Speed Sensor, Left Front|Page 5934