mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Coupler HVAC|Service and Repair|Page 7111 > < Coupler HVAC|Service and Repair
Page 2
background image

4. Pull the spring lock coupling fittings apart.

5. CAUTION:  Do not use metal tools to remove the O-ring seals. They can cause axial scratches across the O-ring seal grooves, resulting in 

refrigerant leaks.

Remove the O-ring seals with a non-metallic tool.

6. CAUTION:  Do not use a screwdriver or similar tool to remove the A/C tube lock coupling spring; this can cause axial scratches across

the O-ring seal grooves resulting in refrigerant leaks.

Remove the A/C tube lock coupling spring with a small hooked wire.

Cleaning

1. Fabricate a cleaning tool from a 1/8-inch diameter brazing rod.

Coupler HVAC|Service and Repair|Page 7111 > < Coupler HVAC|Service and Repair