mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Compressor To Condenser Discharge Line|Page 2169 > < Compressor To Condenser Discharge Line
Page 1
background image

Hose/Line HVAC: Service and Repair
Condenser To Evaporator Line

CONDENSER TO EVAPORATOR LINE

Removal and Installation

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

1. Recover the refrigerant.
2. Remove the condenser outlet fitting nut and disconnect the fitting.

-

Discard the O-ring seal and gasket seal.

-

To install, tighten to 15 Nm (11 lb-ft).

3. Disconnect the evaporator core inlet fitting.

-

Discard the O-ring seals.

4. Remove the condenser-to-evaporator line.
5. To install, reverse the removal procedure.

-

Install a new gasket seal and O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

6. Evacuate, leak test and charge the refrigerant system.

Compressor To Condenser Discharge Line|Page 2169 > < Compressor To Condenser Discharge Line