Shift Interlock Solenoid > < Diagram Information and Instructions|Page 4331
Page 3
background image

3. Connect the molded lead frame to the solenoids.

^

Connect the bulkhead inter-connector by pressing it in place by hand and fully seating the connector in place.

^

Connect the EPC solenoid by pressing it in place by hand and fully seating the connector in place. Make sure that the terminals pass fully
through the connector slots.

^

Connect the TCC by pressing it in place by hand and fully seating the connector in place. Make sure that the terminals pass fully through the
connector slots.

^

Connect the shift solenoid SSA and SSB by pressing it in place by hand and fully seating the connector in place. Make sure that the terminals
pass fully through the connector slots.

4. Install the manual control lever.

5. WARNING:  If equipped with fire suppression system, repower the system. For important safety warnings and procedures, refer to Fire

Suppression System.

If equipped with fire suppression system, repower the system.