Accelerator Pump: Description and Operation

    When the throttle plates are opened  quickly, air flows through the carburetor  almost immediately. Because fuel is heavier  than air, there is a brief
time lag before fuel flow can gain enough speed to maintain  proper air/fuel ratio. During this lag, the  accelerator pump system supplies the necessary 
extra fuel to maintain correct air/fuel  ratio until the other metering systems can respond. When the throttle plates are opened, the diaphragm rod is
pushed  upward, forcing fuel from the pump chamber into the discharge passage. Fuel under pressure moves the discharge check ball off its seat. This
fuel then travels through the pump discharge valve where it enters  the primary venturi through the pump discharge nozzle. 