mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Recall - Emission Control Modifications|Page 3671 > < Recall - Emission Control Modifications|Page 3669
Page 5
background image

FIGURE 4

6.

Refer to Figure 4. Remove the white nylon vacuum line from the crankcase vent assembly. Replace the existing 90~ elbow on the nylon vacuum
line with new elbow (Part Number E3TZ-9E499-C). Connect the elbow and nylon vacuum line to port "A" of the 383013-S three-way "Y" vacuum
connector.

7.

Connect port "C" of the three-way "Y" vacuum connector to the open port on the crankcase vent assembly using a one-inch length of
D0PZ-12226-B vacuum hose (5/32" i.d.).

8.

Connect port "B" of the three-way "Y" vacuum connector to the loose end of the 24-inch vacuum hose (from step # 5). Route the 24-inch vacuum
hose behind the carburetor and down to the crankcase vent assembly taking normal precautions to protect the hose from sharp edges and excessive
heat (such as the base of the EGR valve).

9.

Install a D3FZ-12A091-A vacuum delay valve (# 5, white/black) in the vacuum line connected at the air control side of the combination air bypass
and air control valve, using a 3-inch length of D0PZ-12226-B vacuum hose (5/32" i.d.). Position the white side of the delay valve toward the air
control valve.

VEHICLE EMISSIONS CONTROL INFORMATION (VECI) AND AUTHORIZED MODIFICATIONS DECALS

Recall - Emission Control Modifications|Page 3671 > < Recall - Emission Control Modifications|Page 3669