Condenser HVAC: Service and Repair

CONDENSER CORE

Removal and Installation

NOTE:

-

Installation of a new suction accumulator is not required when repairing the air conditioning (A/C) system except when there is physical evidence
of contamination from a failed A/C compressor or damage to the suction accumulator.

-

If a condenser core leak is suspected, the condenser core must be leak tested before it is removed from the vehicle.

1. With the vehicle in NEUTRAL, position it on a hoist.
2. Recover the refrigerant.
3. Remove the front bumper cover.
4. Remove the 2 condenser core peanut fitting nuts.

-

To install, tighten to 8 Nm (71 lb-in).

5. Remove the 4 condenser core bracket bolts and the 2 condenser core brackets.

-

To install, tighten to 9 Nm (80 lb-in).

6. Remove the condenser core.

7. NOTE:  A new O-ring seal lubricated with clean mineral oil must be installed before installing a new switch.

To install, reverse the removal procedure.
-

Lubricate the refrigerant system with the correct amount of PAG oil.

-

Evacuate, leak test, and charge the refrigerant system.