mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 7290 > < Initial Inspection and Diagnostic Overview|Page 7288
Page 15
background image

-

circuit 760 (PK/LB) short to ground

-

circuit 700 (WH/VT) short to ground

-

circuit 701 (LB/BK) short to ground

-

ajar switches

-

SJB

Test D: The Demand Lighting Is Inoperative

PINPOINT TEST D: THE DEMAND LIGHTING IS INOPERATIVE

D1-D2

Normal Operation

Circuit 1005 (VT/OG) provides voltage to each demand lamp when activated. The demand lamps are grounded through circuit 570 (BK). The battery
saver in the SJB deactivates the voltage and ground circuits after time-out.

Possible Causes

-

circuit 1005 (VT/OG) open

-

circuit 570 (BK) open

Test E: An Individual Interior Lamp Is Inoperative

PINPOINT TEST E: AN INDIVIDUAL INTERIOR LAMP IS INOPERATIVE

Initial Inspection and Diagnostic Overview|Page 7290 > < Initial Inspection and Diagnostic Overview|Page 7288