mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Catalytic Converter - Manifold|Page 3229 > < Catalytic Converter - Manifold|Page 3227
Page 4
background image

If installing a new converter, install the HO2S and the catalyst monitoring sensor using the special tool.
^

Tighten to 47 Nm (35 ft. lbs.).

5. Connect the H02S and the catalyst monitoring sensor electrical connectors.
6. Position the heat shield and install the 6 heat shield bolts.

^

Tighten to 10 Nm (89 inch lbs.).

7. Install the 2 catalytic converter bracket bolts.

^

Tighten to 25 Nm (18 ft. lbs.).

8. Install the exhaust flexible pipe.

Catalytic Converter - Manifold|Page 3229 > < Catalytic Converter - Manifold|Page 3227