mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Main Control Cover and Gasket|Page 3957 > < Main Control Cover and Gasket|Page 3955
Page 6
background image

5. NOTE:  The main control cover gasket is a reusable type. Inspect the gasket for damage. Install a new gasket as necessary.

Install the main control cover gasket.

6. NOTE:  Install the cooler bypass valve studs in locations 3 and 11.

Install the main control cover. Tighten the bolts and studs in the indicated sequence.
^

Tighten to 13 Nm (10 ft. lbs.).

7. Using a small amount of pipe sealant on the threads, install the transaxle drain plug.

^

Tighten to 27 Nm (20 ft. lbs.).

Main Control Cover and Gasket|Page 3957 > < Main Control Cover and Gasket|Page 3955