1. Detach the wire harness pin-type retainer.

2. Remove the lower RH center panel duct screw.

6. Working through the glove compartment opening, detach the wire harness pin-type retainer above the evaporator discharge air temperature sensor.

7. Disconnect the RH temperature blend door actuator electrical connector.

8. NOTICE: Use care to avoid dropping the RH temperature blend door actuator screws into the plenum chamber when removing the

screws. If a screw is dropped into the plenum chamber, it may cause the airflow mode doors to jam, or may cause noise concerns.

NOTE: The RH center instrument panel duct must be slightly repositioned to allow access to the RH temperature blend door actuator screws.

Remove the 2 RH temperature blend door actuator screws.

-

To install, tighten to 3 Nm (27 lb-in).

9. Remove the RH temperature blend door actuator.

10. To install, reverse the removal procedure.