Are the stoplamps illuminated?

Yes

REMOVE the jumper wire. INSTALL a new stoplamp switch. REFER to Stoplamp Switch  See: Brake Light Switch/Service and Repair. TEST the
system for normal operation.

No

REPAIR circuit CCB08 (VT/WH) for an open. TEST the system for normal operation.

-------------------------------------------------
I3 CHECK THE STOPLAMP VOLTAGE SUPPLY CIRCUIT FOR AN OPEN

-

Disconnect: SJB C2280d.

-

Measure the resistance between the stoplamp switch C278-1, circuit SBP02 (YE/RD), harness side and the SJB C2280d-13, circuit SBP02
(YE/RD), harness side.

-

Is the resistance less than 5 ohms?

Yes

GO to I4.

No

REPAIR SBP02 (YE/RD) for an open. TEST the system for normal operation.

-------------------------------------------------
I4 CHECK FOR CORRECT SJB OPERATION

-

Disconnect all the SJB connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the SJB connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new SJB. REFER to Body Control Systems. TEST the system for normal operation.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.

-------------------------------------------------

Pinpoint Test J: One Or More Stoplamps Are Inoperative