mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Main Relay (Computer/Fuel System) > < Intake Air System Components - Exploded View|Page 3004
Page 1
background image

Intake Air Duct: Service and Repair
Air Cleaner Outlet Pipe

Air Cleaner Outlet Pipe

Removal and Installation

NOTICE:  Do not disconnect the Air Cleaner (ACL) outlet pipe from the ACL cover. This is to protect the integrity of the hydrocarbon trap.

1. Disconnect the crankcase vent tube from the ACL outlet pipe.

2. Disconnect the Mass Air Flow (MAF) sensor electrical connector.

3. Release the 2 ACL cover clamps.

4. Loosen the ACL outlet pipe-to-Throttle Body (TB) clamp and remove the ACL outlet pipe and ACL cover assembly.

-

To install, tighten to 4 Nm (35 lb-in).

5. NOTE: The ACL outlet pipe should be securely sealed to prevent unmetered air from entering the engine.

To install, reverse the removal procedure.