mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Refrigerant Oil > < Refrigerant|Capacity Specifications|Page 5384
Page 1
background image

Refrigerant Control Solenoid Valve: Service and Repair

PASSENGER ZONE VALVE

Removal and Installation

NOTE:  Installation of a new receiver/drier is not required when repairing the air conditioning system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the receiver/drier.

1. Recover the refrigerant.
2. Disconnect the passenger zone valve electrical connector.
3. Disconnect the 2 passenger zone valve fittings.

-

Discard the O-ring seals.

-

To install, tighten to 17 Nm (13 lb-ft).

4. Remove the passenger zone valve bracket nut.

-

To install, tighten to 7 Nm (62 lb-in).

5. Remove the passenger zone valve.
6. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

7. Evacuate, leak test and charge the refrigerant system.

Refrigerant Oil > < Refrigerant|Capacity Specifications|Page 5384