mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Air Bag Control Module|Locations|Page 5548 > < Air Bag Control Module|Locations|Page 5546
Page 3
background image

connector into position on the restraints control module (RCM) before using the lever to fully seat the connector. Failure to follow these
instructions may result in component damage and/or system failure.

With the large RCM electrical connector uniformly aligned to the RCM, lightly push in until a subtle audible click is heard and slight
resistance is felt.

4. Connect the RCM electrical connector.

-

Pivot the connector position assurance lever toward the RCM, drawing the connector in to the RCM.
-

Make sure the thumb tab is engaged to the retainer on the RCM and locked in place.

5. Connect the small RCM electrical connector.
6. Position back the carpet on the LH and RH tunnel to its original position.
7. Install the lower LH center instrument panel finish panel.

-

Attach the 2 retainer hooks to the instrument panel brace.

-

Install the pin-type retainer.

Air Bag Control Module|Locations|Page 5548 > < Air Bag Control Module|Locations|Page 5546