mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Refrigerant Oil|Capacity Specifications|Page 6947 > < Refrigerant Control Solenoid Valve|Service and Repair
Page 1
background image

Refrigerant Oil: Capacity Specifications

REFRIGERANT OIL

Total System Capacity ...............................................................................................................................................................................  207 ml (7.0 oz)

A/C COMPRESSOR

If the amount of oil drained from the old A/C compressor is between 85 - 142 ml (3.0 - 5.0 ounces) Add the same amount plus the amount collected
during refrigerant recovery.
If the amount of oil drained from the old A/C compressor is greater than 142 ml (5.0 ounces) Add the same amount plus the amount collected during 
refrigerant recovery.
If the amount of oil drained from the old A/C compressor is less than 85 ml (3.0 ounces) add 85 ml (3.0 ounces) plus the amount collected during 
refrigerant recovery.

NOTE:   Rotate the old A/C compressor shaft 8 to 10 full rotations clockwise while collecting the refrigerant oil in a clean measuring cup. A/C
compressors are shipped without refrigerant oil.

SUCTION ACCUMULATOR OR RECEIVER/DRIER

Drill a 1/2 hole in the old suction accumulator or receiver/drier cylinder and drain the oil into a clean measuring cup. Add the quantity of oil drained,
plus the amount collected during refrigerant recovery and 60 ml (2.0 ounces).

EVAPORATOR CORE .....................................................................................................................................................................  89 ml (3.0 ounces)

CONDENSER CORE ........................................................................................................................................................................  60 ml (2.0 ounces)

EVAPORATOR CORE ORIFICE OR TX VALVE .......................................................................................................................  60 ml (2.0 ounces)

Added to the amount collected during refrigerant recovery.

A/C PRESSURE RELIEF VALVE ...................................................................................................................................................  60 ml (2.0 ounces)

Added to the amount collected during refrigerant recovery.

REFRIGERANT HOSE/LINE ..........................................................................................................................................................  60 ml (2.0 ounces)

Added to the amount collected during refrigerant recovery.

NOTE:  If an excessive amount of refrigerant oil is lost due to a hose rupture/separation or other damage, the total system refrigerant oil capacity
must be added.

O-RING LEAK REPAIR ...................................................................................................................................................................  60 ml (2.0 ounces)

Added to the amount collected during refrigerant recovery.

NOTE:  The amount specified may be used for one or multiple O-ring leak repairs. Do not multiply the refrigerant oil amount by the number of
O-ring leaks being repaired.

PORT LEAK REPAIR ......................................................................................................................................................................  60 ml (2.0 ounces)

Added to the amount collected during refrigerant recovery.

Refrigerant Oil|Capacity Specifications|Page 6947 > < Refrigerant Control Solenoid Valve|Service and Repair