Mariner 2WD V6-3.0L VIN 1 (2006)
Refrigerant Oil: Capacity Specifications
REFRIGERANT OIL
Total System Capacity ............................................................................................................................................................................... 207 ml (7.0 oz)
A/C COMPRESSOR
If the amount of oil drained from the old A/C compressor is between 85 - 142 ml (3.0 - 5.0 ounces) Add the same amount plus the amount collected
during refrigerant recovery.
If the amount of oil drained from the old A/C compressor is greater than 142 ml (5.0 ounces) Add the same amount plus the amount collected during
refrigerant recovery.
If the amount of oil drained from the old A/C compressor is less than 85 ml (3.0 ounces) add 85 ml (3.0 ounces) plus the amount collected during
refrigerant recovery.
NOTE: Rotate the old A/C compressor shaft 8 to 10 full rotations clockwise while collecting the refrigerant oil in a clean measuring cup. A/C
compressors are shipped without refrigerant oil.
SUCTION ACCUMULATOR OR RECEIVER/DRIER
Drill a 1/2 hole in the old suction accumulator or receiver/drier cylinder and drain the oil into a clean measuring cup. Add the quantity of oil drained,
plus the amount collected during refrigerant recovery and 60 ml (2.0 ounces).
EVAPORATOR CORE ..................................................................................................................................................................... 89 ml (3.0 ounces)
CONDENSER CORE ........................................................................................................................................................................ 60 ml (2.0 ounces)
EVAPORATOR CORE ORIFICE OR TX VALVE ....................................................................................................................... 60 ml (2.0 ounces)
Added to the amount collected during refrigerant recovery.
A/C PRESSURE RELIEF VALVE ................................................................................................................................................... 60 ml (2.0 ounces)
Added to the amount collected during refrigerant recovery.
REFRIGERANT HOSE/LINE .......................................................................................................................................................... 60 ml (2.0 ounces)
Added to the amount collected during refrigerant recovery.
NOTE: If an excessive amount of refrigerant oil is lost due to a hose rupture/separation or other damage, the total system refrigerant oil capacity
must be added.
O-RING LEAK REPAIR ................................................................................................................................................................... 60 ml (2.0 ounces)
Added to the amount collected during refrigerant recovery.
NOTE: The amount specified may be used for one or multiple O-ring leak repairs. Do not multiply the refrigerant oil amount by the number of
O-ring leaks being repaired.
PORT LEAK REPAIR ...................................................................................................................................................................... 60 ml (2.0 ounces)
Added to the amount collected during refrigerant recovery.