Fluid - A/T: Service and Repair
Transmission Fluid Cooler - Backflushing and Cleaning

Transmission Fluid Cooler - Backflushing and Cleaning 

1. CAUTION:  Flush with clean transmission fluid only. Do not use solvents, mineral spirits or water-based cleaners.

NOTE:  Rubber hoses must be attached to the ends of the fluid cooler tubes, to aid in connecting them to the cleaner.

Backflush any contaminates out of the oil-to-air cooler by connecting the flushing machine pressure line to number 1 and the return line to number
2.
^

After 5 minutes, stop the machine, reverse the hoses and repeat the flushing.

2. Backflush any contaminants out of the radiator in-tank cooler by connecting the flushing machine pressure line to number 2 and the return line to

number 3.
^

After 5 minutes, stop the machine, reverse the hoses and repeat the flushing.