mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Refrigerant|Testing and Inspection > < Refrigerant|Capacity Specifications|Page 2087
Page 1
background image

Refrigerant: Description and Operation

REFRIGERANT SYSTEM DYE

Fluorescent refrigerant system dye is added to the refrigerant system at the factory to assist in refrigerant system leak diagnosis using an approved
ultraviolet blacklight. It is not necessary to add additional dye to the refrigerant system before diagnosing leaks, even if a significant amount of
refrigerant has been removed from the system. New suction accumulators are shipped with a fluorescent dye wafer included in the desiccant bag which
dissolves after approximately 30 minutes of continued A/C operation. It is not necessary to add dye after flushing or filtering the refrigerant system
because a new suction accumulator is installed as part of the flushing or filtering procedure. Additional refrigerant system dye should only be added if
more than 50% of the refrigerant system lubricant capacity has been lost due to a fitting separation, hose rupture or other damage.

Refrigerant|Testing and Inspection > < Refrigerant|Capacity Specifications|Page 2087