mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Suction Accumulator to Compressor Line|Page 2014 > < Suction Accumulator to Compressor Line|Page 2012
Page 2
background image

3. Position the speed control actuator assembly aside.

1

Disconnect the electrical connector.

2

Detach the wire harness.

3

Remove the 3 nuts and position the speed control actuator aside.
-

To install, tighten to 7 Nm (62 lb-in).

4. Remove the 2 compressor manifold and tube assembly bracket nuts.

-

To install, tighten to 8 Nm (71 lb-in).

5. Disconnect the compressor manifold and tube spring lock coupling at the suction accumulator.

-

Discard the O-ring seals.

6. Remove the front bumper cover.
7. Remove the condenser core inlet fitting nut and disconnect the condenser core inlet fitting.

-

Discard the O-ring seal.
-

To install, tighten to 8 Nm (71 lb-in).

8. Remove the RH splash shield.
9. If equipped, disconnect the engine block heater.

10. Disconnect the A/C compressor electrical connector.
11. Remove the compressor manifold bolt.

-

To install, tighten to 20 Nm (15 lb-ft).

12. Remove the compressor manifold and tube assembly.

-

Discard the O-ring seals.

13. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

14. Evacuate, leak test and charge the refrigerant system.

Suction Accumulator to Compressor Line|Page 2014 > < Suction Accumulator to Compressor Line|Page 2012