mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Fuel Line Coupler|Service and Repair|Page 3857 > < Fuel Line Coupler|Service and Repair
Page 2
background image

Install the quick connect coupling onto the tube until fully seated.

Disconnect - Type II

WARNING:
-

Do not carry lighted tobacco or open flame of any type when working on or near any fuel-related components. Highly flammable vapors
are always present and can ignite. Failure to follow these instructions may result in personal injury.

-

Do not carry personal electronic devices such as cell phones, pagers or audio equipment of any type when working on or near any
fuel-related components. Highly flammable mixtures are present and may be ignited. Failure to follow these instructions can result in
personal injury.

1. Rotate the lock tab on the quick connect coupling.

2. CAUTION:  When reusing liquid or vapor tube connectors, make sure to use compressed air to remove any foreign material from the

connector retaining clip area before separating from the tube. Apply clean engine oil to the end of the tube before inserting the tube into
the connector.

Disconnect the quick connect coupling from the fitting.
-

Pull on the quick connect coupling and separate from the fitting.

Connect - Type II

1. NOTE:  Apply clean engine oil to the O-ring seals.

Rotate the lock tab and install the quick connect coupling onto the fitting.