Mercury Workshop Service and Repair Manuals

Dual Converter Y-Pipe|Page 2559 > < Dual Converter Y-Pipe|Page 2557
Page 3
background image

2. NOTE:  If installing a new dual converter Y-pipe, remove the catalyst monitor sensor for installation in the new dual converter Y-pipe.

NOTE:  Apply anti-seize lubricant to the threads of the catalyst monitor before installation.

Using the special tool, disconnect the RH catalyst monitor sensor.
^

To install, tighten to 47 Nm (35 ft. lbs.).

3. CAUTION:  Do not allow the dual converter Y-pipe to hang from the flexible end. Support the dual converter Y-pipe.

Remove and discard the 2 exhaust catalytic converter nuts.
^

To install, tighten to 47 Nm (35 ft. lbs.).

4. Remove and discard the exhaust hanger from the Y-pipe.
5. Remove and discard the 4 dual converter Y-pipe nuts and remove the Y-pipe.

^

To install, tighten to 47 Nm (35 ft. lbs.).

6. To install, reverse the removal procedure.

^

Install new dual converter Y-pipe gaskets.

Dual Converter Y-Pipe|Page 2559 > < Dual Converter Y-Pipe|Page 2557