Mariner 4WD L4-2.3L VIN Z (2005)
K7-K8
Normal Operation
When the brake pedal is applied, the stoplamp switch allows voltage to flow through circuit 511 (LG). Circuit 511 (LG) provides voltage to the high
mounted stoplamp and the smart junction box (SJB). The SJB then provides voltage to the LH and RH rear lamps through circuits 22 (LB/BK) and
810 (RD/LG), respectively. All the stoplamp are provided ground through circuit 57 (BK).
Possible Causes
-
circuit 22 (LB/BK) open or short to ground
-
circuit 57 (BK) open
-
circuit 511 (LG) open
-
circuit 810 (RD/LG) open or short to ground
-
high mounted stoplamp
-
SJB
Test L: The Stoplamps Are On Continuously
PINPOINT TEST L: THE STOPLAMPS ARE ON CONTINUOUSLY
L1