mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 7645 > < Initial Inspection and Diagnostic Overview|Page 7643
Page 6
background image

A8-A9

Normal Operation

The horn relay B+ power is supplied through circuit 1682 (RD/LB). The horn relay is controlled by the horn switch. The horn relay is grounded
through the horn switches by circuit 6 (YE/LG). When the horn switch is pressed, the horn relay control circuit 6 (YE/LG) is grounded through circuit
57 (BK). The relay is then closed causing B+ voltage to be applied to circuit 1 (DB), sounding the horns.

Possible Causes

-

circuit 1 (DB) open

-

circuit 6 (YE/LG) open

-

circuit 57 (BK) open

-

circuit 1682 (RD/LB) open

-

clockspring

-

horn relay

-

horn

-

horn switch

-

SJB

Test B: The Horn Is Always On

PINPOINT TEST B: THE HORN IS ALWAYS ON

B1