mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Evaporative Emissions Hose > < Evaporative Emission Control Canister|Service and Repair
Page 2
background image

2. Disconnect the battery ground cable.
3. Disconnect the evaporative emission (EVAP) canister vent solenoid electrical connector.
4. Disconnect the fuel vapor hose from the dust separator.

5. Squeeze the coupling opposite of the release tabs and pull to release the fuel vapor tube quick connect coupling from the EVAP canister.
6. Remove the 2 nuts, 3 bolts and the EVAP canister assembly.

-

To install, tighten to 7 Nm (62 lb-in).

7. To install, reverse the removal procedure.
8. Carry out the evaporative emission system leak test.  See: Testing and Inspection/Evaporative Emission System Leak Test
9. Carry out the evaporative emission repair verification drive cycle.  See: Testing and Inspection/Evaporative Emission Repair Verification Drive

Cycle

Evaporative Emissions Hose > < Evaporative Emission Control Canister|Service and Repair