mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Evaporative Emissions Hose|Service and Repair|Page 3307 > < Evaporative Emissions Hose|Service and Repair
Page 2
background image

1. Remove the fuel tank.

2. Squeeze the coupling opposite the release tabs and pull to release the fuel vapor tube quick connect coupling from the fuel vapor control tube

assembly valve fitting.

3. Squeeze the coupling opposite of the release tabs and pull to release the fuel vapor control assembly valve tube quick connect coupling from the

evaporative emissions (EVAP) canister vent solenoid.

4. CAUTION:  When reusing liquid or vapor tube connectors, make sure to use compressed air to remove any foreign material from the

connector retaining clip area before separating the tube.

Using the special tool, disconnect the fuel vapor control tube assembly valve quick connect coupling from the fuel filter vapor tube.
-

Remove the fuel vapor control tube assembly valve.

Installation