2. Remove the lower LH center instrument panel finish panel.
3. Position back the carpet on the LH and RH tunnel to access the RCM.

4. Disconnect the large RCM electrical connector.

1

Pinch the thumb tab and pivot the connector position assurance lever all the way back until it stops.

2

Pull out and disconnect the large RCM electrical connector.

5. Disconnect the small RCM electrical connector.
6. Remove the 3 bolts and the RCM.

Installation