mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2757 > < Initial Inspection and Diagnostic Overview|Page 2755
Page 74
background image

CONNECT the negative battery cable. GO to U4. 

No

GO to Pinpoint Test V.  See: Pinpoint Test V: No Medium Speed Controller Area Network (MS-CAN) Communication, All Modules Are Not
Responding

-------------------------------------------------
U4 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TO VOLTAGE

-

Ignition ON.

-

Measure the voltage between the DLC C251-3, circuit VDB06 (GY/OG), harness side and ground; and between the DLC C251-11, circuit VDB07
(VT/OG), harness side and ground.

-

Is the voltage greater than 6 volts?

Yes

REPAIR the circuit. CLEAR the DTCs. REPEAT the network test with the scan tool. 

No

GO to U5.

-------------------------------------------------
U5 CHECK FOR RESTORED NETWORK COMMUNICATION WITH THE SJB DISABLED

NOTE:  When re-running the network test, the network test application must be first closed or the screen display reverts back to the prior run network
test results.

-

Disconnect: SJB Fuse 5 (10A) .

-

Enter the following diagnostic mode on the scan tool: Network Test .

-

Repeat the network test.

-

Do all other modules pass the network test?

Yes

INSTALL the removed fuse. GO to Pinpoint Test Q.  See: Pinpoint Test Q: The Smart Junction Box (SJB) Does Not Respond To The Scan Tool 

No

INSTALL the removed fuse. GO to U6.

-------------------------------------------------
U6 CHECK FOR RESTORED NETWORK COMMUNICATION WITH THE HVAC MODULE DISABLED

NOTE:  When re-running the network test, the network test application must be first closed or the screen display reverts back to the prior run network
test results.

-

Disconnect: SJB Fuses 37 (10A) and 15 (10A) .

-

Enter the following diagnostic mode on the scan tool: Network Test .

-

Repeat the network test.

-

Do all other modules pass the network test?

Yes

INSTALL the removed fuses. GO to Pinpoint Test L.  See: Pinpoint Test L: The HVAC Module Does Not Respond To The Scan Tool 

No

Initial Inspection and Diagnostic Overview|Page 2757 > < Initial Inspection and Diagnostic Overview|Page 2755