mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2759 > < Initial Inspection and Diagnostic Overview|Page 2757
Page 76
background image

INSTALL the removed fuse. GO to U13.

-------------------------------------------------
U10 VERIFY VEHICLE EQUIPMENT - FCIM

-

Inspect the vehicle for an FCIM.

-

Is the vehicle equipped with an FCIM?

Yes

GO to U11. 

No

GO to U12.

-------------------------------------------------
U11 CHECK FOR RESTORED NETWORK COMMUNICATION WITH THE FCIM DISCONNECTED

NOTE:  When re-running the network test, the network test application must be first closed or the screen display reverts back to the prior run network
test results.

-

Disconnect: FCIM C2402 .

-

Enter the following diagnostic mode on the scan tool: Network Test .

-

Repeat the network test.

-

Do all other modules pass the network test?

Yes

CONNECT the FCIM. GO to Pinpoint Test O.  See: Pinpoint Test O: The Front Controls Interface Module (FCIM) Does Not Respond To The Scan
Tool 

No

CONNECT the FCIM. GO to U12.

-------------------------------------------------
U12 CHECK FOR RESTORED NETWORK COMMUNICATION WITH THE GPSM DISCONNECTED

NOTE:  When re-running the network test, the network test application must be first closed or the screen display reverts back to the prior run network
test results.

-

Disconnect: GPSM C2300 .

-

Enter the following diagnostic mode on the scan tool: Network Test .

-

Repeat the network test.

-

Do all other modules pass the network test?

Yes

CONNECT the GPSM. GO to Pinpoint Test M.  See: Pinpoint Test M: The Global Positioning System Module (GPSM) Does Not Respond To The
Scan Tool 

No

CONNECT the GPSM. GO to Pinpoint Test N.  See: Pinpoint Test N: The Front Display Interface Module (FDIM) Does Not Respond To The Scan
Tool

-------------------------------------------------
U13 CHECK FOR RESTORED NETWORK COMMUNICATION WITH THE IC DISABLED

NOTE:  When re-running the network test, the network test application must be first closed or the screen display reverts back to the prior run network
test results.

-

Disconnect: SJB Fuses 26 (10A), 29 (5A) and 43 (10A) .

-

Enter the following diagnostic mode on the scan tool: Network Test .

Initial Inspection and Diagnostic Overview|Page 2759 > < Initial Inspection and Diagnostic Overview|Page 2757