mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 5347 > < Initial Inspection and Diagnostic Overview|Page 5345
Page 2
background image

-------------------------------------------------
A2 CHECK THE GROUND CIRCUIT FOR AN OPEN

-

Ignition OFF.

-

Measure the resistance between DC/AC inverter C2293A-6, circuit GD182 (BK/GY), harness side and ground.

-

Is the resistance less than 5 ohms?

Yes

GO to A3.

No

REPAIR circuit GD182 (BK/GY). TEST the system for normal operation.

-------------------------------------------------
A3 CHECK THE AC POWER OUTPUT CIRCUITS FOR AN OPEN

-

Disconnect: AC Power Point C2292.

-

Disconnect: DC/AC Inverter C2293B.

-

Measure the resistance between DC/AC inverter C2293B-1, circuit HYA01 (OG/GN), harness side and AC power point C2292-1 circuit HYA01
(OG/GN), harness side.

-

Measure the resistance between DC/AC inverter C2293B-5, circuit HYA02 (OG/WH), harness side and AC power point C2292-3 circuit HYA02
(OG/WH), harness side.

-

Are the resistances less than 5 ohms?

Yes

GO to A4.

No

REPAIR the affected circuit(s). TEST the system for normal operation.

-------------------------------------------------
A4 CHECK THE AC POWER POINT FOR AN OPEN

-

Measure the resistance between AC power point C2292-1, component side and AC power point C2292-2.

Initial Inspection and Diagnostic Overview|Page 5347 > < Initial Inspection and Diagnostic Overview|Page 5345