mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2618 > < Initial Inspection and Diagnostic Overview|Page 2616
Page 44
background image

-------------------------------------------------
R2 CHECK THE HS-CAN TERMINATION RESISTANCE

-

Disconnect: Negative Battery Cable.

-

Measure the resistance between the DLC C251-6, circuit VDB04 (WH/BU), harness side and the DLC C251-14, circuit VDB05 (WH), harness
side.

-

Is the resistance between 54 and 66 ohms?

Yes

GO to R3.

No

Go To Pinpoint Test S.  See: Pinpoint Test S: No High Speed Controller Area Network (HS-CAN) Communication, All Modules Are Not Responding

-------------------------------------------------
R3 CHECK THE HS-CAN (+) AND HS-CAN (-) CIRCUITS FOR A SHORT TO GROUND

-

Measure the resistance between the DLC C251-6, circuit VDB04 (WH/BU), harness side and ground; and between the DLC C251-14, circuit
VDB05 (WH), harness side and ground.

-

Are the resistances greater than 1,000 ohms?

Yes

CONNECT the battery negative cable. GO to R4.

No

Go To Pinpoint Test S.  See: Pinpoint Test S: No High Speed Controller Area Network (HS-CAN) Communication, All Modules Are Not Responding

-------------------------------------------------
R4 CHECK THE HS-CAN (+) AND HS-CAN (-) CIRCUITS FOR A SHORT TO VOLTAGE

-

Ignition ON.

-

Measure the voltage between the DLC C251-6, circuit VDB04 (WH/BU), harness side and ground; and between the DLC C251-14, circuit
VDB05 (WH), harness side and ground.

-

Is the voltage greater than 6 volts?

Yes

REPAIR the circuit. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

Initial Inspection and Diagnostic Overview|Page 2618 > < Initial Inspection and Diagnostic Overview|Page 2616