mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Compressor to Condenser Discharge Line|Page 1226 > < Compressor to Condenser Discharge Line|Page 1224
Page 1
background image

Hose/Line HVAC: Service and Repair
Evaporator Inlet Line

Evaporator Inlet Line - 2.5L, 3.0L (4V)

Removal and Installation

1. Recover the refrigerant.

2. Remove the evaporator inlet line bracket nut.

-

To install, tighten to 8 Nm (71 lb-in).

3. Remove the receiver/drier outlet fitting nut and disconnect the fitting.

-

Discard the O-ring seal and gasket seal.

-

To install, tighten to 15 Nm (133 lb-in).

4. Remove the Thermostatic Expansion Valve (TXV) fitting nut and disconnect the fitting.

-

Discard the gasket seals.

-

To install, tighten to 15 Nm (133 lb-in).

5. Remove the evaporator inlet line.

6. To install, reverse the removal procedure.

-

Install new gasket seals and O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

7. Evacuate, leak test and charge the refrigerant system.

Compressor to Condenser Discharge Line|Page 1226 > < Compressor to Condenser Discharge Line|Page 1224