mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 5712 > < Initial Inspection and Diagnostic Overview|Page 5710
Page 17
background image

-

Are the resistances between 1,000 and 2,000 ohms?

Yes

GO to D23.

No

GO to D26.

-------------------------------------------------
D23 CHECK THE DC/DC CONVERTER FAULT CIRCUIT FOR A SHORT IN THE PCM

-

Connect: PCM C175B.

-

Ignition ON.

-

Measure the voltage between DC/DC converter C1457A-6, circuit CYD04 (BU/OG), harness side and ground.

-

Is the voltage less than 10.5 volts?

Yes

GO to D26.

No

INSTALL a new DC/DC converter. REFER to Direct Current/Direct Current (DC/DC) Converter  . CLEAR the DTCs. REPEAT the self-test.

-------------------------------------------------
D24 CHECK THE DC/DC CONVERTER CIRCUITS FOR AN INTERMITTENT CONCERN

-

Ignition OFF.

-

Connect: DC/DC Converter C1457A (if previously disconnected).

-

Ignition ON.

-

Enter the following diagnostic mode on the scan tool: DataLogger - PCM.

-

While monitoring the PCM DCE and PCM DC/DC converter status (DCE_F) PIDs, carefully wiggle all accessible wiring and connectors
associated with the circuit and monitor the PIDs for a change in state.

-

Do the PIDs indicate a concern while wiggling the harness or connectors?

Yes

REPAIR the affected circuit(s).
Refer to Wiring Diagram Set 12 (Escape/Mariner, Escape Hybrid/Mariner Hybrid) for schematic and connector information.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

CLEAR the DTCs. REPEAT the self-test.

Initial Inspection and Diagnostic Overview|Page 5712 > < Initial Inspection and Diagnostic Overview|Page 5710