mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2854 > < Initial Inspection and Diagnostic Overview|Page 2852
Page 88
background image

-

pushed-out pins

-

Connect the GPSM connector and make it seats correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new GPSM. REFER to Accessories and Optional Equipment. CONNECT all modules. CLEAR the DTCs.

Repeat the network test with the scan tool. 

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules.

-------------------------------------------------
V29 CHECK FOR CORRECT FDIM OPERATION

-

Disconnect the FDIM connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the FDIM connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new FDIM. REFER to Accessories and Optional Equipment. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with
the scan tool. 

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules.

-------------------------------------------------
V30 CHECK FOR CORRECT FCIM OPERATION

-

Disconnect the FCIM connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the FCIM connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new FCIM. REFER to Accessories and Optional Equipment. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with
the scan tool. 

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules.

-------------------------------------------------
V31 CHECK FOR CORRECT ACM OPERATION

-

Disconnect all the ACM connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the ACM connectors and make sure they seat correctly.

Initial Inspection and Diagnostic Overview|Page 2854 > < Initial Inspection and Diagnostic Overview|Page 2852