mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Spring Lock Couplings|Page 3355 > < Spring Lock Couplings|Page 3353
Page 4
background image

2. Disconnect the battery ground cable. For additional information, refer to Battery.

3. NOTE: Carefully release the lock tab to avoid breakage.

Release the quick connect coupling primary lock tab.

4. Rotate the primary lock tab to the fully unlocked position and squeeze the secondary lock tabs to release the locking mechanism.

5. NOTE: When reusing liquid or vapor tube connectors, make sure to use compressed air to remove any foreign material from the connector

retaining clip area before separating from the tube.

Disconnect the quick connect coupling from the tube.

-

Push the locking mechanism outward and separate the quick connect coupling from the tube.

Connect - Type III

1. NOTE: Apply clean engine oil to the end of the tube and the quick connect coupling O-ring seals.

NOTE: Make sure the tube clicks into place when installing it into the quick connect coupling. To make sure the tube is fully seated, pull on the
tube.

Install the quick connect coupling onto the tube until fully seated.

2. NOTE: Make sure the retainer clip clicks into place when installing.

Depress the retainer clip until it is flush with the quick connect coupling housing.

Spring Lock Couplings|Page 3355 > < Spring Lock Couplings|Page 3353