Intake Air Duct: Service and Repair
Air Cleaner Outlet Pipe

Air Cleaner Outlet Pipe

Removal and Installation

1. Disconnect the crankcase ventilation tube-to-Air Cleaner (ACL) outlet pipe quick connect coupling. For additional information, refer to Fuel

Delivery and Air Induction.

2. Loosen the 2 clamps and remove the ACL outlet pipe.

-

To install, tighten to 4 Nm (35 lb-in).

3. NOTE: The ACL outlet pipe should be securely sealed to prevent unmetered air from entering the engine.

To install, reverse the removal procedure.