mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Water Leak - A/C Evaporator/Heater Area|Page 6312 > < Water Leak - A/C Evaporator/Heater Area
Page 2
background image

left) for proper reinstallation. The hoses and valves must be clean and free of foreign material. The check valve rubber flap must face outward, be
snug but have just enough clearance at the center pin to allow it to be freely rotated. It cannot have any holes or gaps at the outer edges. If a fault is
detected, clean or replace the hose assemblies as appropriate and retest the system.

NOTE:

The check valve and hose are serviced as an assembly (E5RY-19858-A/C).

Figure 3 - Article 87-6-3

2.

If no fault was detected in the drain hose assemblies and/or if condensation water is still dripping into the interior of the vehicle, refer to Section
36-01 of the Merkur XR4Ti Shop Manual and remove the evaporator assembly from the vehicle. Remove the upper case half and inspect it for
warpage or damage and replace it if necessary. Similarly, inspect the lower case half. The ribbed drain area beneath the evaporator core and the
drain channels leading to the hoses must be open and clean

(Figure 3). The plastic covers over the drain channels must be tight to the case body. On some vehicles these covers have been found to be loose
and/or warped. When this occurs, blower motor vacuum draws the water out of the channels and into the heater ducts. If this condition is found,
secure the covers with a suitable plastic cement and a light bead of butyl sealer. Use caution not to block the channels.

3.

In a few cases a combination of tolerance stackup and slight warpage of the lower case half may have decreased the clearance between the case
bottom and the evaporator core. This restricts the air flow that normally pushes water into the drain channels and allows some water to flow back
towards the blower motor. To correct this condition, shim the evaporator core up from the case bottom 1/8 inch (4 mm) as shown in Figure 3. Use
a suitable material compatible with aluminum placed across the case bottom ribbed area. An example would be two lengths of brazing rod. Do not
use steel or wood. It is recommended this step be done on all concern vehicles whenever the housing is being serviced.

Water Leak - A/C Evaporator/Heater Area|Page 6312 > < Water Leak - A/C Evaporator/Heater Area