mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Fuel Pump Inertia Switch <--> [Inertia Fuel Shutoff Switch] > < Engine - Stall On Deceleration Or At Idle|Page 760
Page 1
background image

Air Flow Meter/Sensor: Service and Repair

Fig. 23 Vane air meter assembly exploded view

1.

Disconnect battery ground cable.

2.

Remove air cleaner cover bolt and grommet and the air cleaner cover, Fig. 23.

3.

Remove air cleaner element, then disconnect carbon canister hose.

4.

Remove two attaching nuts and the coolant overflow bottle from the air cleaner bracket and secure out of way.

5.

Loosen clamp and disconnect turbocharger air intake tube from vane air meter.

6.

Disconnect vane air meter electrical connector.

7.

Loosen two lower air cleaner bracket attaching screws 

8.

Remove upper air cleaner bracket attaching screw and grommet.

9.

Remove lower half of air cleaner housing, air cleaner bracket, air cleaner outlet tube and the vane air meter as an assembly.

10.

Remove three screws and grommet attaching vane air meter to air cleaner bracket.

11.

Loosen air cleaner outlet tube clamp at vane air meter and remove vane air meter.

12.

Reverse procedure to install.

Fuel Pump Inertia Switch <--> [Inertia Fuel Shutoff Switch] > < Engine - Stall On Deceleration Or At Idle|Page 760