mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Control Components|Page 6651 > < Control Components|Page 6649
Page 3
background image

EATC module wiper voltage value.

Mode Door Actuator
The mode door actuator:
-

uses a cam setup to position the 2 airflow mode doors to direct system airflow to the vehicle interior as determined by the EATC module settings.

-

contains a reversible electric motor.

-

contains a potentiometer. The potentiometer wiper is connected to the actuator output shaft and moves with the output shaft to indicate the position
of the mode door.

5-volt signal is applied to one end of the potentiometer and ground to the other. The voltage available at the wiper indicates the position of the
potentiometer. The expressed value of the actuator wiper voltage is sent to the EATC module and is matched with an expected wiper voltage value.
The EATC module then drives the actuator motor in whichever direction is necessary to make the actuator wiper voltage agree with the expected
EATC module wiper voltage value.

Air Inlet Mode Door Actuator
The air inlet mode door actuator:
-

moves the air inlet door between the FRESH and RECIRC positions on command from the EATC module.

-

contains a reversible electric motor.

-

automatically stops when it reaches the full FRESH or full RECIRC position and does not report its position back to the EATC module.

Control Components|Page 6651 > < Control Components|Page 6649