mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 9783 > < Initial Inspection and Diagnostic Overview|Page 9781
Page 5
background image

-

For a parcel shelf high mounted stoplamp, while applying the brake pedal, measure the voltage between the high mounted stoplamp C475-1,
circuit CCB08 (VT/WH), harness side and the high mounted stoplamp C475-2, circuit GD171 (BK/GY), harness side.

-

Is the voltage greater than 10 volts?

Yes

INSTALL a new high mounted stoplamp. TEST the system for normal operation.

No

REPAIR circuit GD171 (BK/GY) for an open. TEST the system for normal operation.

-------------------------------------------------
K4 CHECK FOR VOLTAGE TO THE LH STOPLAMP

 

-

Disconnect: Inoperative Rear Stoplamp.

-

While applying the brake pedal, measure the voltage between the LH rear lamp C419-1, circuit CCB08 (VT/WH), harness side and ground; or
between the RH rear lamp C418-1, circuit CCB08 (VT/WH), harness side and ground.

-

Is the voltage greater than 10 volts?

Yes

GO to K5.

No

REPAIR circuit CCB08 (VT/WH) for an open. TEST the system for normal operation.

-------------------------------------------------
K5 CHECK FOR VOLTAGE TO THE INOPERATIVE STOPLAMP USING THE CONNECTOR GROUND

Initial Inspection and Diagnostic Overview|Page 9783 > < Initial Inspection and Diagnostic Overview|Page 9781