background image

-

Are the voltages greater than 10 volts?

Yes

GO to C2. 

No

VERIFY the Smart Junction Box (SJB) fuses 29 (5A) or 26 (15A) are OK. If OK, REPAIR the circuit in question. CLEAR the DTCs. If not OK,
REFER to the Wiring Diagrams to identify the possible causes of the circuit short  See: Diagrams/Electrical Diagrams/Diagrams By Number. REPEAT
the network test with the scan tool.

-------------------------------------------------
C2 CHECK THE IPC GROUND CIRCUIT FOR AN OPEN

 

-

Ignition OFF.

-

Disconnect: Negative Battery Cable .

-

For gasoline engine, measure the resistance between the IPC C220-5, circuit GD116 (BK/VT) harness side and ground.

-

For hybrid engine, measure the resistance between the IPC C220-9, circuit GD116 (BK/VT) harness side and ground.

-

Is the resistance less than 5 ohms?

Yes

For gasoline engine, GO to C3. 

For hybrid engine, GO to C5. 

No

REPAIR the circuit. CLEAR the DTCs. REPEAT the network test with the scan tool.