Is the voltage greater than 10 volts?

Yes

GO to D2. 

No

VERIFY the Smart Junction Box (SJB) fuse 42 (10A) is OK. If OK, REPAIR the circuit in question. If not OK, REFER to the Wiring Diagrams to
identify the possible causes of the circuit short  See: Diagrams/Electrical Diagrams/Diagrams By Number. CLEAR the DTCs. REPEAT the network test
with the scan tool.

-------------------------------------------------
D2 CHECK THE PSCM GROUND CIRCUIT FOR AN OPEN

 

-

Ignition OFF.

-

Disconnect: PSCM C1467a .

-

Disconnect: Negative Battery Cable .

-

Measure the resistance between the PSCM C1467a-2, circuit GD104 (BK/GN), harness side and ground.

-

Is the resistance less than 5 ohms?

Yes

GO to D3. 

No

REPAIR the circuit. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
D3 CHECK THE HS-CAN CIRCUITS BETWEEN THE PSCM AND THE DLC FOR AN OPEN

 

-

Measure the resistance between the PSCM C1467b-1, circuit VDB04 (WH/BU), harness side and the DLC C251-6, circuit VDB04 (WH/BU),
harness side.