High-Voltage Converter/Inverter

Pinpoint Tests

Pinpoint Test L: The DC/AC Inverter Does Not Operate Correctly - The AC Power Point LED Indicator is Never On

Refer to Wiring Diagram Set 12 (Fusion/Milan/MKZ, Fusion Hybrid/Milan Hybrid), Charging System for schematic and connector information.  See:
Diagrams/Electrical Diagrams/Diagrams By Number

Normal Operation

The DC/AC inverter receives 12 volts DC at C2293A-1 and C2293A-3 and is grounded at C2293A-6. The incoming DC power is internally converted to
60 Hz, 110 volt AC power that is output to the AC power point from C2293B-1 (power) and C2293B-5 (neutral). If a fault in the system is detected, the
LED flashes or is off when the key is in the ON position. The LED continuously illuminates if the system is operating correctly when the key is in the
ON position.

This pinpoint test is intended to diagnose the following:

-

Fuses

-

Wiring, terminals or connectors

-

DC/AC inverter

-

AC power point

 

PINPOINT TEST L: THE DC/AC INVERTER DOES NOT OPERATE CORRECTLY - THE AC POWER POINT LED INDICATOR IS
NEVER ON

NOTICE:  Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

-------------------------------------------------
L1 CHECK DC/AC INVERTER VOLTAGE CIRCUIT

 

-

Ignition OFF.

-

Disconnect: DC/AC Inverter C2293A.

-

Ignition ON.

-

Measure the voltage between DC/AC inverter C2293A-3, circuit CBP35 (YE/GY), harness side and ground.